AMBUS® Link

The new M-Bus data centre

Product names: AMBUS®
Applications: Commercial buildings / Building technology, Systems integration
Medium: Software / Systems engineering
Process: Data processing / Evaluation
ambus_link_250_1

The intelligent M-Bus data centre facilitates the configuration, operation and monitoring of M-Bus sys-tems as complete systems featuring modern, customer-friendly operation. Thanks to the integrated web server, the device can be controlled remotely via a network connection and the consumption data can be collected in many different ways.

Features

M-Bus centre with integrated web server

For 20, 60, 120 or 250 M-Bus meters

Data logger with plug-in data memory

10/100 Base Ethernet

Easy language selection

Transparent access to M-Bus

Logger files in different formats

Customer benefits

Remote data readout via Internet browser

Also for large M-Bus networks

Very easy operation

Recording of data for analysis purposes

For new systems and for retrofitting existing systems

Configuration and analysis via mobile devices

Suitable for energy data management in accordance with ISO 50001

Simple integration into BACnet/IP

Technical data, certificates and approvals

Basic data

Power Supply

24VDC

Power consumption

max. 1A

Temperature range

0 - 55°C

Display

Backlit LCD display (128x64 dots)

Weight

app. 400g

Installation

35mm DIN rail

Housing

Polycarbonate, recyclable, non-combustible

Evaluation

Web server / chart

Data export

As JSON or CSV Datei

Data memory

Micro SD card (must have at least 32 GB of free memory)

Firmware update

Yes, possible

Configuration

Local and remote configuration using a web browser

Inputs

3x M-Bus
2x Temperature PT1000 (-20°C to +100°C)
4x S0

Outputs

2x Relays

Interfaces

1x Ethernet 10/100 Base RJ45
1x USB type A
1x USB type B

M-Bus

Baud rates

300, 600, 1200, 2400, 4800, 9600

Compatibility

Heat, water, gas and electricity meter with M-Bus in accordance with
EN 13757-2,-3 (previously EN1434-3)

Level converter

Integrated
Can be operated in a transparent manner via USB type B

M-Bus closed-circuit current

Max. 375mA (250 x 1.5mA)

Number of M-Bus slaves

Max. 250 (see order information)

Electrical isolation

Yes

Short-circuit protection

Yes

Overload protection


Yes

BACnet/IP

Specification

All M-Bus meters registered on the AMBUS® Link are automatically converted in BACnet/IP objects

BBMD

Yes

Protocol Implementation Conformance Statement

The PICS document can be found on our website at http://www.aquametro.com/ambuslink

Approvals and standards

Safety

CE Mark

EMC measurement

EN 610000-6.2

Immunity

EN 61000-6-3

M-Bus standard

EN 13757-2,-3

Energy management

Suitable for ISO 50001

BACnet

Certified

Ajax Loader